SciPro

PRODUCT SEARCH

------------------------------

Canada 1-800-268-1956

United States 1-888-433-7777

Email info at scipro.com

A Better Way to get More from LC Analysis  Download our NEWEST Brochure!

Read More About The Low Temperature Evaporative Light Scattering Detectore (LT-ELSD) Technology.

Sedere has generated a large number of Application Notes that describe the very extensive use of the Sedex LT-ELSD in LC and SFC.  See List Here.

You can also refer to Sedere's ELSD Bibliography.  Download Bibliography

Created with GIMPNEW SEDEX Model 100 LT-ELSD provides the New Ultimate solution in Low-Temperature Evaporative Light-Scattering Detection for HPLC and U-HPLC, resulting from a New Optical Head design based on a new High Power Laser.  This provides the highest signal to noise ratio for all compounds.

This detector shows a number of innovative features including the ability to select the best nebulizer and a unique Low-Temperature Technology. The evaporation drift tube design optimizes both efficiency and sensitivity. In addition, you can control the system locally or via a PC thanks to drivers. A remote shut down mode is provided to minimize consumable cost and enhance system lifetime. 

A series of 4 nebulizers are available to optimize the user's applications.  In HPLC, two nebulizers cover the flow rate range from 50ul/min to 2ml/min, additionally there is one nebulizer optimized for U-HPLC and another one specifically for SFC.  All these nebulizers can be readily and quickly changed to meet the requirements of the application.
Download Sedex 100LT Spec Sheet

Sedere 90 LTSEDEX Model 90 LT-ELSD provides the Ultimate solution in Low-Temperature Evaporative Light-Scattering Detection for HPLC and U-HPLC, resulting from a New Optical Head design based on a Laser

This detector shows a number of innovative features including the ability to select the best nebulizer and a unique Low-Temperature Technology. The evaporation drift tube design optimizes both efficiency and sensitivity. In addition, you can control the system locally or via a PC thanks to drivers. A remote shut down mode is provided to minimize consumable cost and enhance system lifetime. 

A series of 6 nebulizers are available to optimize the user's applications.  In HPLC, four nebulizers cover the flow rate range from 5ul/min to 5ml/min, additionally there is one nebulizer optimized for U-HPLC and another one specifically for SFC.  All these nebulizers can be readily and quickly changed to meet the requirements of the application.
Download Sedex 90LT Brochure
Download Sedex 90LT Spec Sheet
Download Sedex 90LT Pharmaceutical Analysis Poster

Sedex 85 LTSEDEX Model 85 LT-ELSD provides the Standard solution in Low-Temperature Evaporative Light-Scattering Detection for HPLC. 

This detector shows a number of innovative features including the ability to select the best nebulizer and a unique Low-Temperature Technology. The evaporation drift tube design optimizes both efficiency and sensitivity. In addition, you can control the system locally or via a PC thanks to drivers. A remote shut down mode is provided to minimize consumable cost and enhance system lifetime.

A series of 6 nebulizers are available to optimize the user's applications.  In HPLC, four nebulizers cover the flow rate range from 5ul/min to 5ml/min, additionally there is one nebulizer optimized for U-HPLC and another one specifically for SFC.  All these nebulizers can be readily and quickly changed to meet the requirements of the application. Download Sedex 85LT Spec Sheet

Sedex 80 LTSEDEX Model 80 LT-ELSD provides the Cost-Effective solution in Low-Temperature Evaporative Light-Scattering Detection for HPLC. 

Compared to the previous SEDEX Model 75 LT-ELSD, this detector presents a number of innovative features including a unique Low-Temperature Technology. The evaporation drift tube design optimizes both efficiency and sensitivity. In addition, you can control the system locally or via a PC (with RS-232 activated Models) thanks to drivers. A remote shut down mode is also provided to minimize cost and enhance system lifetime.

A set of 2 nebulizers are available to optimize the user's applications.  One for HPLC and one for Flash Chromatography.  These nebulizers cover the flow rate range from 100ul/min to 5ml/min.  These nebulizers can be readily and quickly changed to meet the requirements of the application. Download Sedex 80LT Spec Sheet

Sedex FPSEDEX Model FP combines simplicity, reliability and robustness for all your purification works.  It provides the Cost-Effective solution in Low-Temperature Evaporative Light-Scattering Detection for purification by preparative HPLC, preparative SFC and Flash Chromatography. 

Control of the system can be done either locally or via a PC. A remote shut down mode is also provided to minimize cost and enhance system lifetime.

A dedicated nebulizer and an innovative cell design minimize band broadening.  This nebulizer covers the flow rate range from 100ul/min to 5ml/min and can be readily and quickly mounted and dismounted.  With SAGA (Sedex Automated Gain Adjustment), an innovative gain control available when it is driver-controlled by software, the Sedex FP automatically adapts the gain setting to avoid any off-scale saturation of the detector.  It also has an optimized Liquid Flow Path to avoid any clogging or contamination.

Sedex LCNEW! SEDEX Model LC combines high sensitivity,reliability and accuracy for all your analytical works.  It provides the Cost-Effective solution in Low-Temperature Evaporative Light-Scattering Detection for standard Liquid Chromatography.

Control of the system can be done either locally or via a PC. A remote shut down mode is also provided to minimize cost and enhance system lifetime.

A dedicated nebulizer and an innovative cell design minimize band broadening.  This nebulizer covers the flow rate range from 200ul/min to 2ml/min and can be readily and quickly mounted and dismounted.  With SAGA (Sedex Automated Gain Adjustment), an innovative gain control available when it is driver-controlled by software, the Sedex FP automatically adapts the gain setting to avoid any off-scale saturation of the detector.

For more information, contact us.