Probes – CNS

Download our 2018 SciPro Price Sheet for pricing on Probes

 Order Form

MAB 2 – pkg. of 3

MAB-2The MAB 2 series of microdialysis probes come with a 35kD cut-off, PES membrane. Standard probes have a 14 or 20mm shaft length and membrane lengths of 1, 2, 3 or 4mm. Two advantages of these probes are they can be stored dry and can be sterilized with 1210C steam.  Although these probes are warranted for single use only, it is common to reuse them.  Disposable & Re-usable guide cannulas are available.

Specifications: Ordering: 
Membrane:35 kD cut-off, PES1mm PES/14mm ShaftMAB 2.14.1
Membrane OD:0.6 mm2mm PES/14mm ShaftMAB 2.14.2
Shaft:PI tubing3mm PES/14mm ShaftMAB 2.14.3
Shaft OD:0.5 mm4mm PES/14mm ShaftMAB 2.14.4
Inner cannula:PI tubing1mm PES/20mm ShaftMAB 2.20.1
Inlet/oulet cannula:PEEK tubing2mm PES/20mm ShaftMAB 2.20.2
Inlet dead volume:0.7 μl3mm PES/20mm ShaftMAB 2.20.3
Outlet dead volume:2.4 μl4mm PES/20mm ShaftMAB 2.20.4

MAB 6 – pkg. of 3

MAB-6The MAB 6 series of microdialysis probes come with a 15kD cut-off, PES membrane. Standard probes have a 14 or 20mm shaft length and membrane lengths of 1, 2, 3 or 4mm. Two advantages of these probes are they can be stored dry and can be sterilized with 1210C steam. Although these probes are warranted for single use only, it is common to reuse them.  Disposable & Re-usable guide cannulas are available.

Specifications: Ordering: 
Membrane:15 kD cut-off, PES1mm PES/14mm ShaftMAB 6.14.1
Membrane OD:0.6 mm2mm PES/14mm ShaftMAB 6.14.2
Shaft:PI tubing3mm PES/14mm ShaftMAB 6.14.3
Shaft OD:0.5 mm4mm PES/14mm ShaftMAB 6.14.4
Inner cannula:PI tubing1mm PES/20mm ShaftMAB 6.20.1
Inlet/oulet cannula:PEEK tubing2mm PES/20mm ShaftMAB 6.20.2
Inlet dead volume:0.7 μl3mm PES/20mm ShaftMAB 6.20.3
Outlet dead volume:2.4 μl4mm PES/20mm ShaftMAB 6.20.4

MAB 9 – pkg. of 3

MAB-9The MAB 9 series of microdialysis probes come with a 6kD cut- off, PES membrane. Standard probes have a 14 or 20mm shaft length and membrane lengths of 1, 2, 3 or 4mm. Two advantages of these probes are they can be stored dry and can be sterilized with 1210C steam. Although these probes are warranted for single use only, it is common to reuse them.  Disposable & Re-usable guide cannulas are available.

Specifications: Ordering: 
Membrane:6 kD cut-off, PES1mm PES/14mm ShaftMAB 9.14.1
Membrane OD:0.6 mm2mm PES/14mm ShaftMAB 9.14.2
Shaft:PI tubing3mm PES/14mm ShaftMAB 9.14.3
Shaft OD:0.5 mm4mm PES/14mm ShaftMAB 9.14.4
Inner cannula:PI tubing1mm PES/20mm ShaftMAB 9.20.1
Inlet/oulet cannula:PEEK tubing2mm PES/20mm ShaftMAB 9.20.2
Inlet dead volume:0.7 μl3mm PES/20mm ShaftMAB 9.20.3
Outlet dead volume:2.4 μl4mm PES/20mm ShaftMAB 9.20.4