MAB 2 / 6 / 9 Series of Microdialysis Guide Cannulas
- Designed for repeated use
- 1/4 turn locking mechanism
- 14mm & 20 mm shaft standard
- 6mm & 12 mm insertion depths
- Custom lengths available
Read More
The MAB 2/6/9 Guide Cannula is reusable, made from KEL-F and stainless steel. Two different versions, fitting MAB 2/6/9.14 and MAB 2/6/9.20 probes, are available as standard products. The guide cannula is made for repeated use meaning that the dental cement is removed with Acetone between experiments. Note that the dummy head should not be put in acetone.
Specifications: | Ordering: | ||
---|---|---|---|
Shaft: | Stainless Steel | 14mm Shaft | MAB 2/6/9.14.GS |
Shaft OD: | 1.0 mm | 20mm Shaft | MAB 2/6/9.20.G |
Guide Head: | Kel-F, 7.5mmOD | ||
Insertion Depth: | 6.0 and 12mm | ||
Guides for custom designed probes are also available. |
MAB 6 Series Microdialysis Guide Cannulas
- Designed for repeated use
- Metal clip locking mechanism
- 14mm & 20 mm shaft standard
- 6mm & 12 mm insertion depths
- Custom lengths available
Read More
The MAB 6 Guide Cannula is reusable, made from KEL-F and stainless steel. Two different versions, fitting MAB 6.14 and MAB 6.20 probes, are available as standard products. The guide cannula is made for repeated use meaning that the dental cement is removed with Acetone between experiments. Note that the dummy head should not be put in acetone.
Specifications: | Ordering: | ||
---|---|---|---|
Shaft: | Stainless Steel | 14mm Shaft | MAB 6.14.G |
Shaft OD: | 1.0 mm | 20mm Shaft | MAB 6.20.G |
Guide Head: | Kel-F, 5x5mm | ||
Insertion Depth: | 6.0 and 12mm | ||
Guides for custom designed probes are also available. |
MAB 4 Series Microdialysis Guide Cannulas
- Designed for repeated use
- Metal clip locking mechanism
- 15mm shaft standard
- 7mm insertion depths
- Custom lengths available
Read More
The MAB 4 Guide Cannula is reusable, made from KEL-F and stainless steel. This guide is designed for use with MAB4Cu probes. The guide cannula is made for repeated use meaning that the dental cement is removed with Acetone between experiments. Note that the dummy head should not be put in acetone.
Specifications: | Ordering: | ||
---|---|---|---|
Shaft: | Stainless Steel | 15mm Shaft | MAB 4.15.G |
Shaft OD: | 0.38 mm | ||
Guide Head: | Kel-F, 5x5mm | ||
Insertion Depth: | 7.0 mm | ||
Guides for custom designed probes are also available. |
MAB Multi Series Microdialysis Guide Cannulas
- Designed for single use
- Metal free construction
- 14mm, 15mm & 20 mm shaft standard
- 10mm, 11mm & 16 mm insertion depths
- Custom lengths available
Read More
The MAB Intracerebral Guide Cannula is for single use. Four different versions, fitting MAB 2/6/9.14, MAB 2/6/9.20, MAB 4 and MAB 10 probes, are available as standard products. If placed in Acetone the guide cannula will dissolve. Thin dimensions are ideal for multiple probe placement.
Specifications: | Ordering: | pkg. of 10 | |
---|---|---|---|
Shaft: | Polyurethane | 14mm Shaft | MAB 2/6/9.14.IC |
Shaft OD: | 1.0 or 0.5 mm | 20mm Shaft | MAB 2/6/9.20.IC |
Guide Head: | TPE, 3.0 mm | 15mm Shaft | MAB 4.15.IC |
Insertion Depth: | 10.0, 16.0 and 11 mm | 15mm Shaft | MAB 5.15.IC |
8mm Shaft | MAB 10.8.IC | ||
Insertion Depth: | 4.5 mm | 8mm Shaft | MAB 12.8.IC |
Guides for custom designed probes are also available. |
User Guides for Guide Cannulas
Open Guide for Reusable Guide Cannulas
Open Guide for Disposable Guide Cannulas
Contact us for more information on which Guide Cannula to use